1.1 · Why MPD: the narrow window
Lesson 1.1 · free preview. On DHW-1 the gap between a kick and losses is only 0.4 ppg, and the pumps alone use 0.31 of it. This lesson works the numbers and shows why no single mud weight can drill this section, and what managed pressure drilling changes.
Key numbers · DHW-1
- Window: pore 12.3 ppg at TD, fracture 12.7 ppg at the 9⅝” shoe (0.4 ppg)
- Hydrostatic pressure: 0.052 × 12.0 × 12,000 = 7,488 psi
- Annular friction at 450 gpm: 163 psi at the shoe, 243 psi at TD (ECD swing at the shoe 0.31 ppg)
- Mud A, 12.0 ppg: 12.0 < 12.3 pore on every connection → kick
- Mud B, 12.5 ppg: 12.81 at the shoe while drilling > 12.7 → losses
- MPD: keep 12.0 ppg mud, add 69 psi back pressure while drilling and 312 psi on a connection → bottom hole held at 12.5 ppg (7,800 psi)
RULE: pore + trip margin + ECD swing must fit under the fracture pressure. If it doesn’t, no mud weight works: control the pressure from the surface.
Try it: put DHW-1 into the free MPD-1 ECD/BHP calculator, change the flow rate, and find the back pressure that keeps the bottom at 12.5 ppg with the pumps on and off.
Next: Lesson 1.2, hydrostatic pressure and why every pressure in drilling is written as a mud weight.
Narration: synthetic voice · numbers checked by a drilling/process engineer. DHW-1 is a generic training well. This lesson does not replace well-control certification.