Episode 3 · Heater and choke in HYSYS (Set and Adjust)
Heater H-100 takes the well fluid from 30 to 60 °C in two coil passes, with the choke HV-134 between them (Route A). The Night Shift Episode 3 hand calc says 786 kW. This episode builds H-100 in Aspen HYSYS V11 as two Heater blocks around the valve, holds the inlet at exactly 30 °C with a Set and an Adjust, and finds where the hand calc loses 108 kW.
| Check | HYSYS | Hand calc (Night Shift Ep 3) |
|---|---|---|
| H-100 duty, 30 → 60 °C | 894 kW (coil 1 387.7 + coil 2 506.2) | 786 kW |
| Sensible heat, Σ m·Cp × 30 K | 728 kW (24.26 kW/K) | 733 kW (24.44 kW/K) |
| Liquid that boils into the gas | 650 kg/h (517 oil + 132 water) | not counted |
| Heating 30 → 60 °C at 30 barg | 788 kW | 733 kW |
| Choke make-up (whole-stream cooling) | 106 kW (3.6 °C) | 53 kW (2.1 °C) |
| Heater sized to the hand calc | V-100 at 56.3 °C, not 60 | — |
| Choke outlet vs hydrate (coil 1 out 45 °C) | 41.9 vs 3.9 °C, margin 38 °C | — |
| Fuel gas at η 0.75 (assumed) | 118 Sm³/h (LHV 36.3 MJ/Sm³) | 102 Sm³/h (LHV 37 assumed) |
The coil split never changes the total. The choke keeps the enthalpy constant, so moving the coil 1 outlet from 30 to 60 °C shifts duty between the coils and keeps the total at 894 kW. The split only sets the choke temperature.
Arrival temperature sweep: 40 °C: 637 kW · 35 °C: 766 kW · 30 °C: 894 kW · 25 °C: 1,021 kW · 20 °C: 1,148 kW · 15 °C: 1,274 kW · 10 °C: 1,401 kW · 5 °C: 1,526 kW. Every 1 °C colder adds 25.4 kW.
The lesson: the heat capacities agree with the hand calc within 1 %. The gap is the liquid that boils into the gas as the stream heats and as the choke drops the pressure. A one-line hand calc has no latent-heat term, so on a live two-phase well stream it runs 14 % low.
Rule: use one line of hand calc to check a heater. Size it from the simulation, at the coldest arrival temperature.
Honest limit: the coil split (45 °C), the coil pressure drop (0) and the burner efficiency (75 %) are assumed; the C7+ heating value is estimated (0.6 % of the total); the coldest arrival temperature and the design margin are not set yet (Process Design and your company standard).
Aspen HYSYS is a trademark of Aspen Technology, Inc.; Design Hub is not affiliated with AspenTech.