▸ §00 · PAGE

Design Hub Plant Design Basis

The design basis of the Design Hub Plant, the plant built step by step in the Design Hub Process Design series on YouTube. Every value comes from the series’ single basis file. Use it to follow every episode. To keep a copy, download the one-page PDF (rev 0.71).

Design Hub Plant · Design Basis

rev 0.71 · 12-Nov-2026 · the plant built in the Design Hub “Process Design” series · designhubindia.org

FEED

Gas10 MMSCFDSG 0.65
Oil2,000 bbl/dSG 0.82
Water1,500 bbl/dSG 1.05
Gas standard60 °F, 14.696 psia379.49 scf/lbmol
Live oil at V-100778 kg/m³13.97 m³/h actual

CONDITIONS + CASES

Separator normal12 barg60 °C
Max operating13 barg
Well shut-in35 bargupstream of SDV-100
Casesnormal 1 · max ×1.2turndown ×0.3

EQUIPMENT + LINES

V-100ID 1,800 × 6,000 T/T mmSA-516 Gr 70
Design15 barg / 120 °CMAWP 16.74 barg
MDMT · CA-29 °C · 3 mmhydrotest 21.76 barg
PSV-100set 15 barg3L4 (API 526)
6″-P-100135 barg / 180 °C300#
H-100894 kW normal · 1,192 kW fired30 → 60 °C
Choke HV-13430 → 12.5 bargbetween the heater coils
K-100 (proposed)12 → 62 barg2 stages, reciprocating

SEPARATOR GAS COMPOSITION, mol % (dry) · water in gas 1.59 mol %

N2CO2C1C2C3iC4nC4iC5nC5nC6C7+
1.011.9987.985.312.350.430.520.140.130.080.07

HEAT + MASS BALANCE · normal case · H-100 894 kW

No.StreamP, bargT, °Ckg/h
1Well fluid, manifold to H-100 coil 1303030,818
2H-100 coil 1 out, to choke HV-134304530,818
3Choke out, to H-100 coil 212.541.930,818
4H-100 out, 6″-P-1001 > SDV-100 > V-100 N112.56030,818
5V-100 gas, N2 > PV-10012609,520
6Fuel gas to H-100 burner——94
7Gas to K-100 suction (via V-110)12609,426
8V-100 oil, N3 > LV-101126010,864
9Oil to T-100 after LV-101≈ 06010,864
10T-100 flash gas, to vent / flare≈ 060130
11Stabilised oil, T-100 > P-101 > export≈ 06010,734
12V-100 water, N4 > LV-102 > produced water126010,434

ROUTE

production manifold (shut-in 35 barg) → H-100 indirect bath heater: coil pass 1 -> choke -> coil pass 2 → 6″-P-1001 (300#, B3A side) → SDV-100 (spec break 300# | 150#) → 6″x12″ expander → 12″-P-1102 (A1A 150#) → V-100 N1 12″
A generic teaching plant: not a real project, a client job or a measured analysis. The composition is synthetic (sweet, no Hâ‚‚S); C7+ is one hypothetical component. Streams 1–4 come from the simulator heater case (V-100 inlet 12.5 barg), 5, 8 and 12 from the separator case (12.0 barg), 10 from a Peng-Robinson flash to atmospheric at 60 °C (an upper bound). K-100 and the plant downstream are proposed and confirmed in a later episode. Check every value against your own project’s codes and data before you use it. © Design Hub · designhubindia.org