The design basis of the Design Hub Plant, the plant built step by step in the Design Hub Process Design series on YouTube. Every value comes from the series’ single basis file. Use it to follow every episode. To keep a copy, download the one-page PDF (rev 0.71).
Design Hub Plant · Design Basis
rev 0.71 · 12-Nov-2026 · the plant built in the Design Hub “Process Design” series · designhubindia.org
FEED
| Gas | 10 MMSCFD | SG 0.65 |
| Oil | 2,000 bbl/d | SG 0.82 |
| Water | 1,500 bbl/d | SG 1.05 |
| Gas standard | 60 °F, 14.696 psia | 379.49 scf/lbmol |
| Live oil at V-100 | 778 kg/m³ | 13.97 m³/h actual |
CONDITIONS + CASES
| Separator normal | 12 barg | 60 °C |
| Max operating | 13 barg | |
| Well shut-in | 35 barg | upstream of SDV-100 |
| Cases | normal 1 · max ×1.2 | turndown ×0.3 |
EQUIPMENT + LINES
| V-100 | ID 1,800 × 6,000 T/T mm | SA-516 Gr 70 |
| Design | 15 barg / 120 °C | MAWP 16.74 barg |
| MDMT · CA | -29 °C · 3 mm | hydrotest 21.76 barg |
| PSV-100 | set 15 barg | 3L4 (API 526) |
| 6″-P-1001 | 35 barg / 180 °C | 300# |
| H-100 | 894 kW normal · 1,192 kW fired | 30 → 60 °C |
| Choke HV-134 | 30 → 12.5 barg | between the heater coils |
| K-100 (proposed) | 12 → 62 barg | 2 stages, reciprocating |
SEPARATOR GAS COMPOSITION, mol % (dry) · water in gas 1.59 mol %
| N2 | CO2 | C1 | C2 | C3 | iC4 | nC4 | iC5 | nC5 | nC6 | C7+ |
|---|
| 1.01 | 1.99 | 87.98 | 5.31 | 2.35 | 0.43 | 0.52 | 0.14 | 0.13 | 0.08 | 0.07 |
HEAT + MASS BALANCE · normal case · H-100 894 kW
| No. | Stream | P, barg | T, °C | kg/h |
|---|
| 1 | Well fluid, manifold to H-100 coil 1 | 30 | 30 | 30,818 |
| 2 | H-100 coil 1 out, to choke HV-134 | 30 | 45 | 30,818 |
| 3 | Choke out, to H-100 coil 2 | 12.5 | 41.9 | 30,818 |
| 4 | H-100 out, 6″-P-1001 > SDV-100 > V-100 N1 | 12.5 | 60 | 30,818 |
| 5 | V-100 gas, N2 > PV-100 | 12 | 60 | 9,520 |
| 6 | Fuel gas to H-100 burner | — | — | 94 |
| 7 | Gas to K-100 suction (via V-110) | 12 | 60 | 9,426 |
| 8 | V-100 oil, N3 > LV-101 | 12 | 60 | 10,864 |
| 9 | Oil to T-100 after LV-101 | ≈ 0 | 60 | 10,864 |
| 10 | T-100 flash gas, to vent / flare | ≈ 0 | 60 | 130 |
| 11 | Stabilised oil, T-100 > P-101 > export | ≈ 0 | 60 | 10,734 |
| 12 | V-100 water, N4 > LV-102 > produced water | 12 | 60 | 10,434 |
ROUTE
production manifold (shut-in 35 barg) → H-100 indirect bath heater: coil pass 1 -> choke -> coil pass 2 → 6″-P-1001 (300#, B3A side) → SDV-100 (spec break 300# | 150#) → 6″x12″ expander → 12″-P-1102 (A1A 150#) → V-100 N1 12″
A generic teaching plant: not a real project, a client job or a measured analysis. The composition is synthetic (sweet, no Hâ‚‚S); C7+ is one hypothetical component. Streams 1–4 come from the simulator heater case (V-100 inlet 12.5 barg), 5, 8 and 12 from the separator case (12.0 barg), 10 from a Peng-Robinson flash to atmospheric at 60 °C (an upper bound). K-100 and the plant downstream are proposed and confirmed in a later episode. Check every value against your own project’s codes and data before you use it. © Design Hub · designhubindia.org