Pump NPSH Calculator: NPSH Available (NPSHa)

NPSH available (NPSHa) is the head the liquid brings to the pump inlet above its own vapour pressure. If it falls below the pump’s NPSH required (NPSHr), the liquid boils inside the eye of the impeller and the pump cavitates. This free calculator works out NPSHa from the suction side and checks it against NPSHr plus the margin you set.

How to use it

  1. Press P-101 normal. Tank T-100 holds 6.0 m of oil above the pump and the strainer is clean: NPSHa is 5.50 m against 1.5 m required. PASS.
  2. Press P-101 alarm night. The level is down to 5.0 m and the strainer is plugged (4.0 m of loss, 0.32 bar across it): NPSHa drops to 0.70 m. The pump cavitates.
  3. Read the two numbers under the sheet: the lowest tank level that still passes, and the largest strainer loss allowed. At 5.0 m the strainer can lose 2.20 m, which is 0.177 bar. The example’s strainer dP alarm (PDI-142, assumed 0.15 bar) sits below that, so it sounds before the pump runs out of margin. Your strainer dP alarm is an NPSH alarm.
  4. Now enter your own pump: suction vessel pressure and vapour pressure (both absolute), density, level, losses, the vendor’s NPSHr and your project’s margin.

The formula

NPSHa = (Ps − Pv) × 10⁵ / (ρ × g) + z − hf,line − hf,str

Ps is the absolute pressure on the liquid surface in the suction vessel and Pv the vapour pressure at pumping temperature, both in bar a. ρ is the liquid density in kg/m³, g = 9.80665 m/s², z the liquid level above the pump centre line in m (negative when the pump lifts), and the losses are in metres of the pumped liquid at the flow you check.

For a liquid stored at its boiling point (a tank that has just flashed its gas, a separator, a condensate drum) Pv equals Ps and the pressure term is zero. Then only the static head minus the suction losses is left, which is why a falling level and a dirty strainer together are dangerous.

How to raise NPSHa

  • Raise the liquid level in the suction vessel, or set a higher low-level trip.
  • Lower the pump, or raise the vessel, so z grows.
  • Use a bigger or shorter suction line with fewer fittings, so hf,line falls.
  • Keep the strainer clean, and alarm on its differential pressure.
  • Cool the liquid or raise the vessel pressure, so Ps − Pv grows.

About the P-101 example

P-101 is the oil export pump of the Design Hub training plant, used in Night Shift Episode 4. Its values are an example, assumed: NPSHr 1.5 m at rated flow, the tank levels and the losses are illustrative, and the 1.0 m margin is an assumption, not a code value. Density 820 kg/m³ is the plant basis stock-tank figure. For a real pump, use the vendor’s NPSHr curve at your flow and your project’s margin rule.

This is a teaching tool, not a design tool. More free tools are on the Design Hub Labs page.