From the Design Hub Process Design series, episode 2. The plant and its numbers start in episode 1, and its design basis is free on one page.
Your separator runs at 12 barg. Why is it designed for 15, and what does it cost you if you pick 14? This worked example sets the design pressure of V-100, a 1.8 m × 6 m three-phase separator in SA-516 Gr 70, in three steps.
1. A vessel has a ladder of pressures, not one
| Rung | barg |
|---|---|
| normal operating | 12 |
| max operating | 13 |
| PSV set | 15 |
| design | 15 |
| relief (10 %) | 16.5 |
| MAWP | 16.74 |
| fire (21 %) | 18.15 |
| hydrotest | 21.76 |
Design pressure is the number you hand the vessel designer. The margin on top of maximum operating is company practice, not code. MAWP is worked back from the plate you actually buy, so it is usually higher than design. The PSV is set at or below MAWP, never above; it may overpressure 10 % when it relieves and 21 % in a fire. Hydrotest is 1.3 × MAWP. The code here is ASME VIII Division 1; in the 2021 edition the relief rules moved to Section XIII, so check your project’s edition.
2. Step 1: design pressure
Maximum operating is 13 barg. Margin rule: 10 % or 1 bar, whichever is more. 10 % of 13 is 1.3, so 14.3 barg, rounded up to 15 barg.
3. Step 2: the plate, then the MAWP
The full mechanical design of this vessel (shell, heads, nozzles, hydrotest) is in the Pressure Vessel Design series. Here is the short version. ASME VIII-1 UG-27: t = P·R / (S·E − 0.6·P), with P = 1.5 MPa, R = 903 mm (inside radius in the corroded condition), S = 138 MPa at 120 °C, E = 0.85 (spot radiography). That gives 11.64 mm, plus 3 mm corrosion allowance = 14.64 mm. Plates come in steps: 14 mm is too thin, so 16 mm.
Worked backwards, the 16 mm shell holds 16.74 barg: the MAWP. The heads are good for 17.4, so the shell governs. The Class 150 nozzle flanges are rated 16.94 bar at 120 °C, just above. The 1.74 bar between design and MAWP came free, only because plates come in steps.
4. Step 3: the PSV gap
PSV-100 is set at 15 barg. Maximum operating over set is 13 ÷ 15 = 86.7 %. Common practice keeps a spring-loaded PSV below 90 %; closer than that it simmers and leaks in a normal upset. Relief at 10 % over set is 16.5 barg, fire at 21 % is 18.15 barg, and hydrotest is 21.76 barg.
5. What if you pick 14, or 35?
| Design | Shell | MAWP, barg | Shell + heads, kg | Max op / PSV set |
|---|---|---|---|---|
| 14 barg | 14 mm | 14.19 | 4,542 | 93 % |
| 15 barg | 16 mm | 16.74 | 5,197 | 87 % |
| 35 barg | 32 mm | 36.58 | 10,384 | 37 % |
14 barg saves 655 kg of steel, but the PSV sits at 93 % of set and simmers. 35 barg, the full shut-in pressure, about doubles the steel (+5,187 kg). 15 barg is the answer.
6. The red-pen mistake: the spec break in the wrong place
The wells can shut in at 35 barg. Upstream of SDV-100 the line is Class 300. If the drawing changes to Class 150 at the separator nozzle, the pipe between SDV-100 and the vessel is Class 150 with the wells behind it. At the line’s 180 °C design temperature Class 150 is good for 14.6 bar (only 18.9 bar even at 60 °C); Class 300 holds 44.3. The choke restricts flow, not pressure. Put the spec break where the pressure source ends: at SDV-100, the valve that can isolate it.
Rule: maximum operating below PSV set; PSV set at or below design; design at or below MAWP. Write all four on the datasheet.
Check your own vessel
Write your own ladder on the datasheet and test it against the four inequalities above. The free calculators in Design Hub Labs and the courses (two free lessons each) go further. Next in the series: the heat and mass balance.
Thickness and MAWP follow UG-27 with the stated S and E; flange ratings are ASME B16.5. Teaching plant, not a real project.
Check the shell yourself
Free Lab: Pressure Vessel Shell Lab (UG-27 thickness and MAWP). Full course: Pressure Vessel Design to ASME VIII Div 1, first 2 lessons free.