From the Design Hub Process Design series, episode 1. Watch the video: Oil & Gas Process Design: Full Worked Example (3-D). The plant’s design basis is free on one page: Design Hub Plant design basis.
You get 10 MMSCFD of wet gas and a blank sheet. Before anyone buys a pipe, a process engineer makes 18 decisions, in order. This worked example sets up the plant that every Design Hub series uses (an early production facility with a heater, a three-phase separator, an oil pump (check its suction with the free NPSH calculator) and tank, a gas compressor and scrubber, and a flare), then closes its mass balance by hand.
1. Process design is a chain of documents
The order matters, because each document feeds the next. Change the basis late and everything after it is done twice.
- Design basis (DBM)
- Heat and mass balance
- PFD
- Equipment list + process datasheets
- Line list
- P&ID
- Control philosophy + cause & effect
- Relief summary (PSV + flare)
- HAZOP report
Under all nine sits one law: mass in = mass out. Gas changes volume with pressure and temperature; its mass does not. A balance only closes in kilograms.
2. The design basis
Gas 10 MMSCFD (SG 0.65), oil 2,000 bbl/d (SG 0.82), water 1,500 bbl/d (SG 1.05). Separator V-100 at 12 barg and 60 °C. Wells shut in at 35 barg. Maximum case 1.2 × normal.
3. The mass balance, step by step
Three streams, two steps each: field units to a flow, then to kg/h.
| Stream | Field units | Step 1 | Step 2 | kg/h |
|---|---|---|---|---|
| Gas | 10 MMSCFD | ÷ 379.49 ft³/lb-mol → 498 kmol/h | × M 18.83 | 9,376 |
| Oil | 2,000 bbl/d | × 0.159 ÷ 24 → 13.25 m³/h | × 820 kg/m³ | 10,864 |
| Water | 1,500 bbl/d | × 0.159 ÷ 24 → 9.94 m³/h | × 1050 kg/m³ | 10,434 |
| Total | 30,674 | |||
Gas, in detail. A standard cubic foot is measured at 60 °F and 1 atm, where one lb-mol of ideal gas fills 379.49 ft³. 10,000,000 ÷ 379.49 = 26,351 lb-mol/d × 0.4536 = 11,953 kmol/d ÷ 24 = 498 kmol/h. Molar mass = 0.65 × 28.97 = 18.83. So 498 × 18.83 = 9,376 kg/h.
Total: 30,674 kg/h (30.7 t/h), and the same leaves the plant. At maximum flow it is 36.8 t/h.
4. Mass and volume tell different stories
By mass, gas is only 31 % of what enters V-100 (oil 35 %, water 34 %). By actual volume at 12 barg it is 98 %: 1,033.6 m³/h of gas against 13.25 m³/h of oil and 9.94 m³/h of water. Balance in mass; size on actual volume. (Episode 5 checks which one actually sets V-100’s diameter, and for this plant it is the liquid.)
5. The red-pen mistake: standard vs actual m³/h
10 MMSCFD converted and divided by 24 is 11,799 m³/h, but that is gas at 1 atm. At 12 barg and 60 °C the real volume is 1,033.6 m³/h. Size on the standard number, and the vessel and every gas line come out about 11 times too big for the gas they will ever see.
Rule: convert standard volume to mass before you size anything. Balance in kg/h. Size on actual volume.
6. The 18 decisions
12 of the 18 decisions already have a checked number from another Design Hub series (pressure vessels, P&ID, instrumentation, piping, CFD, PSV). The rest are worked in the episodes that follow: design pressure (Ep 2), heat and mass balance (Ep 3), hydrates and the heater (Ep 4), separator sizing (Ep 5 and 6), and on through relief, flare and HAZOP.
Try it yourself
Download the one-page design basis and close the balance on your own sheet before you check it against the table above. Then check V-100’s shell in the free Pressure Vessel Shell Lab, or start the Process Engineering Foundations course (first lessons free).
The numbers come from the episode’s calc file, checked against the P&ID and instrumentation series that use the same plant. The plant is a teaching plant, not a real project.
Work it on your own numbers
Free tools: Design Hub Labs (shell thickness, nozzle, saddle, NPSH and more). Full course: Process Engineering Foundations for Oil & Gas EPC, first lessons free.