Lesson 1 · Oil & Gas Process Design: Full Worked Example

You get 10 MMSCFD of wet gas and a blank sheet. This lesson sets up the plant every later lesson uses, puts the nine design documents in order, and closes the mass balance by hand.

In this lesson

  • The nine process documents, in the order they’re made, and why the order matters.
  • The Design Hub Plant’s design basis.
  • A mass balance from field units to kg/h, for gas, oil and water.
  • Why mass and volume tell different stories, and which one you size on.

The nine documents, in order

  1. Design basis (DBM)
  2. Heat and mass balance
  3. PFD
  4. Equipment list + process datasheets
  5. Line list
  6. P&ID
  7. Control philosophy + cause & effect
  8. Relief summary (PSV + flare)
  9. HAZOP report

Key numbers

Gas 10 MMSCFD, SG 0.65 (M = 18.83)
Oil 2,000 bbl/d, 820 kg/m³
Water 1,500 bbl/d, 1050 kg/m³
Separator V-100 12 barg, 60 °C
Mass in = mass out 30,674 kg/h (30.7 t/h); max case ×1.2 = 36.8 t/h
Gas share 31 % by mass, 98 % by actual volume
Gas, actual 1,033.6 m³/h at 12 barg (standard: 11,799 m³/h)

The worked steps

  1. Gas: 10,000,000 scf/d ÷ 379.49 scf/lb-mol = 26,351 lb-mol/d × 0.4536 = 11,953 kmol/d ÷ 24 = 498.0 kmol/h.
  2. Molar mass = 0.65 × 28.965 = 18.827, so 498.0 × 18.827 = 9,376 kg/h.
  3. Oil: 2,000 bbl/d × 0.159 m³/bbl ÷ 24 = 13.25 m³/h × 820 = 10,864 kg/h.
  4. Water: 1,500 bbl/d → 9.94 m³/h × 1050 = 10,434 kg/h.
  5. Total: 30,674 kg/h. The same mass leaves the plant.

Red pen: the common mistake

10 MMSCFD converted and divided by 24 is 11,799 m³/h, but that’s gas at 1 atm. At 12 barg the real volume is 1,033.6 m³/h. Size on the standard number and the vessel and every gas line are sized for about 11 times the gas they’ll ever see.

Field note

The first revision of a heat and mass balance usually changes equipment sizes. Don’t size anything you can’t trace to a signed basis.

Rule: Convert standard volume to mass before you size anything. Balance in kg/h. Size on actual volume.

Practice

The wells are tested at 12 MMSCFD of the same gas (SG 0.65). What’s the gas mass flow in kg/h?

Worked answer

12,000,000 ÷ 379.49 × 0.4536 ÷ 24 = 597.6 kmol/h × 18.827 = 11,252 kg/h. That’s 1.2 × the normal gas flow: the plant’s maximum case (11,252 kg/h).

Quiz

  1. What do you balance a plant in?
    1. Standard m³/h
    2. Actual m³/h
    3. kg/h
    Answer

    C

  2. 10 MMSCFD is 11,799 m³/h at standard conditions. What is it at 12 barg in V-100?
    1. 11,799 m³/h
    2. 1,033.6 m³/h
    3. 498 m³/h
    Answer

    B

  3. Which document comes first?
    1. Equipment list
    2. Design basis
    3. Line list
    Answer

    B