Lesson 1 · Oil & Gas Process Design: Full Worked Example
You get 10 MMSCFD of wet gas and a blank sheet. This lesson sets up the plant every later lesson uses, puts the nine design documents in order, and closes the mass balance by hand.
In this lesson
- The nine process documents, in the order they’re made, and why the order matters.
- The Design Hub Plant’s design basis.
- A mass balance from field units to kg/h, for gas, oil and water.
- Why mass and volume tell different stories, and which one you size on.
The nine documents, in order
- Design basis (DBM)
- Heat and mass balance
- PFD
- Equipment list + process datasheets
- Line list
- P&ID
- Control philosophy + cause & effect
- Relief summary (PSV + flare)
- HAZOP report
Key numbers
| Gas | 10 MMSCFD, SG 0.65 (M = 18.83) |
| Oil | 2,000 bbl/d, 820 kg/m³ |
| Water | 1,500 bbl/d, 1050 kg/m³ |
| Separator V-100 | 12 barg, 60 °C |
| Mass in = mass out | 30,674 kg/h (30.7 t/h); max case ×1.2 = 36.8 t/h |
| Gas share | 31 % by mass, 98 % by actual volume |
| Gas, actual | 1,033.6 m³/h at 12 barg (standard: 11,799 m³/h) |
The worked steps
- Gas: 10,000,000 scf/d ÷ 379.49 scf/lb-mol = 26,351 lb-mol/d × 0.4536 = 11,953 kmol/d ÷ 24 = 498.0 kmol/h.
- Molar mass = 0.65 × 28.965 = 18.827, so 498.0 × 18.827 = 9,376 kg/h.
- Oil: 2,000 bbl/d × 0.159 m³/bbl ÷ 24 = 13.25 m³/h × 820 = 10,864 kg/h.
- Water: 1,500 bbl/d → 9.94 m³/h × 1050 = 10,434 kg/h.
- Total: 30,674 kg/h. The same mass leaves the plant.
Red pen: the common mistake
10 MMSCFD converted and divided by 24 is 11,799 m³/h, but that’s gas at 1 atm. At 12 barg the real volume is 1,033.6 m³/h. Size on the standard number and the vessel and every gas line are sized for about 11 times the gas they’ll ever see.
Field note
The first revision of a heat and mass balance usually changes equipment sizes. Don’t size anything you can’t trace to a signed basis.
Rule: Convert standard volume to mass before you size anything. Balance in kg/h. Size on actual volume.
Practice
The wells are tested at 12 MMSCFD of the same gas (SG 0.65). What’s the gas mass flow in kg/h?
Worked answer
12,000,000 ÷ 379.49 × 0.4536 ÷ 24 = 597.6 kmol/h × 18.827 = 11,252 kg/h. That’s 1.2 × the normal gas flow: the plant’s maximum case (11,252 kg/h).
Quiz
- What do you balance a plant in?
- Standard m³/h
- Actual m³/h
- kg/h
Answer
C
- 10 MMSCFD is 11,799 m³/h at standard conditions. What is it at 12 barg in V-100?
- 11,799 m³/h
- 1,033.6 m³/h
- 498 m³/h
Answer
B
- Which document comes first?
- Equipment list
- Design basis
- Line list
Answer
B
Next: Lesson 2, design pressure · Free: the one-page design basis · Article: the worked example in text